Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Ortodontia ; 49(4): 313-318, jul./ago. 2016. tab,, graf
Article in Portuguese | LILACS, BBO | ID: biblio-875201

ABSTRACT

O objetivo deste trabalho foi avaliar a alteração dimensional linear dos elásticos ortodônticos sendo submetidos ao tempo de armazenagem em saliva artificial a 37ºC durante o período imediato (T0), 24 horas (T24) e 30 dias (T30). Os grupos de elásticos foram divididos em cinco cores com dez (n=10) amostras por grupo: cinza (C); verde (V); preta (P); rosa (R) e transparentes (T), e marcas comerciais: Morelli (a); 3M Unitek (b); GAC (c). Utilizou-se a máquina de análise de dimensão (perfilômetro) da marca Mitutoyo, que avaliou a alteração de dimensão conforme as distâncias de extremidade dos elásticos e os fatores envolvidos como o tempo de armazenamento e a marca comercial. Em seguida, os dados foram analisados estatisticamente, obtendo os resultados e realizadas as tabelas, gráficos e as correlações lineares. Para esta avaliação foram utilizados os testes Anova e de Tukey (p < 0,01). Os resultados apontaram os seguintes valores: grupo V ­ t0:3,09 (± 0,24), t24:3,12 (± 0,36) e t30d:3,15 (± 0,22); grupo T ­ t0:3,07 (± 0,16), t24:3,10 (± 0,15), t30d:3,14 (± 0,10), grupo P ­ t0:3,13 (± 0,24), t24:,16 (± 0,19), t30d:3,18 (± 0,20); grupo R ­ t0:3,08 (± 0,25), t24:3,11 (± 0,14), t30d:3,13 (± 0,18); grupo C ­ t0:3,15 (± 0,31), t24h:3,18 (± 0,15) e t30d:3,19 (± 0,59). O grupo P apresentou diferença estatisticamente significante em relação aos demais. As marcas comerciais apresentaram pequenas alterações dimensionais, aceitáveis clinicamente de acordo com a literatura. Concluiu-se que os pigmentos, que determinam a cor específica dos elásticos, são fatores que interferem na propriedade deste material. O tempo de armazenamento é determinante e fundamental para avaliação do comportamento de estabilidade do material polimérico.


The objective of this study was to evaluate the linear dimensional change of orthodontic elastics submitted to the storage in artificial saliva 37ºC at baseline (T0), 24-hour (T24), and at 30-day (T30) periods. The groups (n=10) were divided into five colors: gray (C), green (V), black (P), pink (R), and clear (T) with the following brands: Morelli (a), 3m Unitek (b), and GAC (c). A profilometer (Mitutoyo) was used to analyze the dimensional changes. Next, means were obtained also with tables, plots, and linear correlations. The Anova and Tukey´s tests (p<0.01) were used to evaluate data. The results showed that group V presented values: t0:3.09 (± 0.24), t24:3.12 (± 0.36) and t30d:3.15 (± 0.22); T group: t0:3.07 (± 0.16), t24:3.10 (± 0.15), t30d:3.14 (± 0.10), P group: t0:3.13 (± 0.24), t 24:16 (± 0.19), t30d:3.18 (± 0.20); R group: t0:3.08 (± 0.25), t24:3.11 (± .14), t30d:3.13 (± 0.18), C group: t0:3.15 (± 0.31), t24h:3.18 (± 0.15) and t30d: 3.19 (± 0.59), being statistically different from the P group compared to other groups. The commercial brands presented small dimensional changes and according the literature. It can be concluded that pigments can interfere with the elastic property.The storage time is fundamental to evaluate the stability of the polymeric material.


Subject(s)
Elastomers/analysis , Latex/analysis , Materials Testing , Prosthesis Coloring , Orthodontic Appliances , Saliva, Artificial
2.
Ortodontia ; 48(6): 527-533, nov.-dez.2015. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-783997

ABSTRACT

As ligaduras elásticas são consideradas importantes fontes de força na movimentação ortodôntica. No entanto, apresentam a desvantagem de não serem capazes de liberar níveis de forças constantes no meio bucal, por sofrerem alterações em suas propriedades físicas (dimensão, características individuais), prejudicando suas propriedades mecânicas. O objetivo deste trabalho foi avaliar a degradação de força das ligaduras elásticas ortodônticas convencionais e temáticas. Dezoito grupos experimentais foram avaliados (n=10), tendo como fatores em estudo o formato das ligaduras, temática (Orthosource) e convencional (Morelli); o tempo de armazenagem em saliva artificial a 37°C (24 horas e 30 dias) e a cor (vermelho, rosa e azul). Para a determinação da intensidade das forças liberadas, todas as ligaduras elásticas foram distendidas quatro vezes o valor do seu comprimento original (1 mm), em máquina de ensaio universal Instron 5965 à velocidade constante de 5,08 mm/min, sendo a resistência máxima à tração registrada em N. Os dados foram analisados pelos testes Anova e Tukey para comparações entre os grupos (α=0,05). Os resultados demonstraram que a degradação de força após 24 horas foi muito superior nas ligaduras elásticas convencionais (24,09%, 18,90% e 14,45%) do que nas ligaduras temáticas (1,31%, 2,55% e 2,99%) nas cores vermelho, rosa e azul, respectivamente. Após 30 dias, a degradação de força continuou sendo superior nas ligaduras elásticas convencionais (33,20%, 27,23% e 21,87%), embora a degradação nas ligaduras temáticas tenha aumentado drasticamente neste período (11,89%, 15,55% e 18,53%) nas cores vermelho, rosa e azul, respectivamente...


Elastic ties are considered an important source of force for orthodontic movement. However, they present the disadvantage of not being able to release constant force levels overtime in the oral environment due to changes in their physical properties (dimension, individual characteristics) affecting their mechanical properties. The purpose of this study was to evaluate the force degradation of conventional and thematic orthodontic elastic ties. Eighteen experimental groups were evaluated (n=10) having as variables the elastic tie format of two commercial brands, thematic (Orthosource) and conventional (Morelli), the storage time in artificial saliva at 37°C (immediate, 24 hours and 30 days) and color (red, pink and blue). To determine the magnitude of the forces released, all elastic ties were stretched four times their original size (1 mm) in a universal testing machine (Instron 5965) at a constant speed rate of 5.08 mm/min with the tensile strength measured in N. The data were analyzed by Anova and Tukey statistical tests for multiple comparisons among the groups (α=0.05). The results demonstrated that force degradation after 24h was much greater for the conventional (24,09%, 18,90% and 14,45%) than for the thematic elastic ties (1,31%, 2,55% and 2,99%) in red, pink and blue colors, respectively. After 30 days, force degradation continued to be greater with the conventional elastic ties (33,20%, 27,23% and 21,87%) although force degradation with the thematic elastic ties increased dramatically (11,89%, 15,55% and 18,53%) in red, pink and blue colors, respectively...


Subject(s)
Humans , Elastomers/analysis , Ligation/adverse effects , Ligation , Materials Testing , Orthodontic Appliances
3.
J. appl. oral sci ; 21(2): 157-162, Mar-Apr/2013. graf
Article in English | LILACS | ID: lil-674357

ABSTRACT

Objective: This study evaluated the effect of temperature and curing time on composite sorption and solubility. Material and Methods: Seventy five specimens (8×2 mm) were prepared using a commercial composite resin (ICE, SDI). Three temperatures (10°C, 25°C and 60°C) and five curing times (5 s, 10 s, 20 s, 40 s and 60 s) were evaluated. The specimens were weighed on an analytical balance three times: A: before storage (M1); B: 7 days after storage (M2); C: 7 days after storage plus 1 day of drying (M3). The storage solution consisted of 75% alcohol/25% water. Sorption and solubility were calculated using these three weights and specimen dimensions. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U Tests (α=5%). Results: The results showed that time, temperature and their interaction influenced the sorption and solubility of the composite (p<0.05). At 60°C, the composite sorption showed an inverse relationship with the curing time (p<0.05). The composite cured for 5 s showed higher sorption for the 40 s or 60 s curing times when compared with all temperatures (p<0.05). Curing times of 20 s and 40 s showed similar sorption data for all temperatures (p>0.05). The 60°C composite temperature led to lower values of sorption for all curing times when compared with the 10°C temperature (p<0.05). The same results were found when comparing 10°C and 25°C (p<0.05), except that the 20 s and 40 s curing times behaved similarly (p>0.05). Solubility was similar at 40 s and 60 s for all temperatures (p>0.05), but was higher at 10°C than at 60°C for all curing times (p<0.05). When the composite was cured at 25°C, similar solubility values were found when comparing the 5 s and 10 s or 20 s and 40 s curing times (p>0.05). Conclusion: In conclusion, higher temperatures or longer curing times led to lower sorption and solubility values for the composite tested; however, this trend was only significant in specific combinations of temperature and curing times.


Subject(s)
Curing Lights, Dental , Composite Resins/chemistry , Polymerization/radiation effects , Absorption , Adsorption , Composite Resins/radiation effects , Materials Testing , Reference Values , Solubility , Statistics, Nonparametric , Surface Properties , Temperature , Time Factors
4.
Ortho Sci., Orthod. sci. pract ; 6(23): 265-269, 2013. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-707579

ABSTRACT

O objetivo do presente trabalho é avaliar a resistência ao cisalhamento de tubos de colagem ortodônticos de diferentes marcas comerciais. Foram utilizados 30 tubos de colagem ortodônticos divididos em cinco grupos (n = 6): I (Rocky Mountain Orthodontics, Colorado, USA), II (Ormco Corporation, Glendora, Califórnia), III (3M-Unitek, Minnesota, USA), IV (G&H Wire Company, Hanover, Alemanha) e V (Dentsplay GAC International, NY, USA). Os mesmos foram colados no ponto mais convexo e centralizados na face do dente bovino e levados à máquina universal de ensaios mecânicos Emic DL 2000, a uma velocidade de 0,5 mm por minuto. Foi avaliada a força necessária para descolar os tubos ortodônticos. Os dados foram analisados pela análise de variância (ANO-VA) e teste de Fisher. Os tubos ortodônticos do grupo III necessitaram de uma força maior para que ocorresse a descolagem, esses resultados foram estatisticamente significantes em relação aos demais (p < 0,01), que se descolaram com força menor. O grupo IV apresentou os menores valores para descolar, entretanto, sem diferença estatística com o grupo V (p > 0,01). Conclui-se que tubos ortodônticos podem ser utilizados como alternativa para a bandagem dos molares. Três das cinco marcas comerciais suportaram tanto a força ortodôntica como a mastigatória, enquanto que duas marcas comerciais suportaram somente as forças ortodônticas.


The purpose of this study is to evaluate the shear bond strength (SBS) of orthodontic molar tubes from different trademarks. Thirty molar tubes were divided into five groups (n = 6): I (Rocky Mountain Orthodontics, Colorado, USA), II (Ormco Corporation, Glendora, Califórnia), III (3M-Unitek, Minnesota, USA), IV (G&H Wire Company, Hanover, Alemanha) e V (Dentsplay GAC International, NY, USA). The tubes were bonded to bovine teeth and placed on an Emic DL2000 testing machine with a crosshead speed of 0.5 mm/minute. The amount of force required to debond the tubes was assessed. Data were analyzed using two-way variance analysis (ANOVA) and the Fisher test. There was a statistically significant difference (p < 0.001) on shear bond strength. Othodontic tubes of group III presented thehigher SBS, while group IV showed the lower SBS, with no statistical difference in relation to group V (p > 0.01). It was concluded that bonding tubes may be used as an alternative to molar bands. Three of the five brands assessed in this study, supported both, orthodontic and masticatory forces, while two of them supported only the orthodontic forces.


Subject(s)
Dental Debonding , Shear Strength
5.
RSBO (Impr.) ; 9(4): 468-473, Oct.-Dec. 2012. ilus, tab
Article in English | LILACS | ID: lil-755727

ABSTRACT

Introduction: The uniqueness of dental morphology plays an important role in Forensic Odontology, especially for human identifications, in which a single tooth can provide information for dental identification. Objective: To address the importance of a permanent lower canine with two roots for dental identification considering the internal and external morphology of the canine roots. Case report: To report a forensic case in which a two-rooted permanent lower canine was found in a decomposed human body. Conclusion: Although the victim was not identified by the dental parameter, it was observed that this type of morphological variation is of little incidence in some populations, therefore constituting a valuable tool for dental human identifications.

6.
Article in English | IMSEAR | ID: sea-146789

ABSTRACT

Objective: To compare four different surface treatment methods and determine which produces adequate bond strength between ceramic brackets and facets of porcelain (feldspathic), and evaluate the Adhesive Remnant Index (ARI) scores. Materials and Methods: Ten facets of porcelain specimens with glazed surfaces were used for each group. The specimens were randomly assigned to one of the following treatment conditions of the porcelain surface: (1) no surface treatment (control group), (2) fine diamond bur + orthophosphoric acid gel 37%, (3) hydrofluoric acid (HFL) 10%, and (4) HFL 10% + silane. Ceramic brackets were bonded with the adhesive cement Transbond XT. The shear bond strength values were measured on a universal testing machine at a crosshead speed of 0.5 mm/min. Results: There was a significant difference (P<0.05) between the control group and all other groups. There was no significant difference (P<0.05) between treated porcelain surface with diamond bur + orthophosphoric acid gel 37% (4.8 MPa) and HFL 10% (6.1 MPa), but the group treated with HFL 10% had clinically acceptable bond strength values. The group treated with HFL 10% + silane (17.5 MPa) resulted in a statistically significant higher tensile bond strength (P<0.05). In group 4, 20% of the porcelain facets displayed damage. Conclusion: Etching of the surface with HFL increased the bond strength values. Silane application was recommended to bond a ceramic bracket to the porcelain surface in order to achieve bond strengths that are clinically acceptable.

7.
Dental press j. orthod. (Impr.) ; 17(4): 1-8, July-Aug. 2012. ilus, tab
Article in English | LILACS | ID: lil-653493

ABSTRACT

OBJECTIVE: To evaluate the bonding strength of the ceramic bracket and composite resin restoration interface, using four types of treatment on the base of the bracket. METHODOLOGY: 48 photoactivated composite resin discs were used (FiltekTM Z250) contained in specimens and divided into 4 groups of 12 specimens for each group according to the type of treatment performed on the base of the brackets. Once the brackets were bonded, the specimens were subjected to shear stress carried out in a universal testing machine (MTS: 810 Material Test System) calibrated with a fixed speed of 0.5 mm / minute. The values obtained were recorded and compared by means of appropriate statistical tests - analysis of variance and then Tukey's test. RESULTS AND CONCLUSIONS: The surfaces of ceramic brackets conditioned with 10% hydrofluoric acid for 1 minute, followed by aluminum oxide blasting, 50µ, after silane application and primer application, was considered the best method to prepare surfaces of ceramic brackets prior to orthodontic esthetic bonding.


OBJETIVO: avaliar a resistência à união da interface entre braquete cerâmico e restauração de resina composta, empregando quatro tipos de tratamento na base do braquete. MÉTODOS: foram utilizados 48 discos de resina fotoativada (Filtek® Z250) incluídos em corpos de prova, divididos em quatro grupos, com 12 espécimes em cada grupo, de acordo com o tipo de tratamento realizado na base do braquete. Uma vez colados os braquetes, os corpos de prova foram submetidos à tensão de cisalhamento, realizado numa máquina universal de ensaios (MTS: 810 Material Test System) calibrada com velocidade fixa de 0,5mm/min. Os valores obtidos foram registrados e comparados por meio de médias, utilizando-se testes estatísticos adequados (análise de Variância e, posteriormente, teste de Tukey). RESULTADOS E CONCLUSÕES: o condicionamento das superfícies dos braquetes cerâmicos com ácido hidrofluorídrico a 10% por 1 minuto, seguido do jateamento com óxido de alumínio com 50um de tamanho, e posterior aplicação do silano e, depois, aplicação de adesivo, foi considerado o melhor método para o preparo de superfícies de braquetes cerâmicos previamente à colagem estética ortodôntica.

8.
Braz. dent. j ; 20(5): 410-413, 2009. ilus, tab
Article in English | LILACS | ID: lil-537548

ABSTRACT

The aim of this study was to evaluate the Knoop hardness after 15 min and 24 h of different shades of a dual-cured resin-based cement after indirect photoactivation (ceramic restoration) with 2 light-curing units (LCUs). The resin cement Variolink II (Ivoclar Vivadent) shade XL, A2, A3 and opaque were mixed with the catalyst paste and inserted into a black Teflon mold (5 mm diameter x 1 mm high). A transparent strip was placed over the mold and a ceramic disc (Duceram Plus, shade A3) was positioned over the resin cement. Light-activation was performed through the ceramic for 40 s using quartz-tungsten-halogen (QTH) (XL 2500; 3M ESPE) or light-emitting diode (LED) (Ultrablue Is, DMC) LCUs with power density of 615 and 610 mW/cm2, respectively. The Koop hardness was measured using a microhardness tester HMV 2 (Shimadzu) after 15 min or 24 h. Four indentations were made in each specimen. Data were subjected to ANOVA and Tukey's test (a=0.05). The QTH LCU provided significantly higher (p<0.05) KHN values than the LED LCU. When the post-cure times were compared for the same shade, QTH and LED at 24 h provided significantly higher (p<0.05) KHN values than at 15 min. It may be concluded that the Knoop hardness was generally dependent on the LCU and post-cure time. The opaque shade of the resin cement showed lower Knoop hardness than the other shades for both LCUs and post-cure times.


Este estudo avaliou a dureza Knoop após 15 min e 24 h de diferentes cores do cimento resinoso dual após fotoativação indireta com 2 fontes de luz. O cimento resinoso Variolink II (Ivoclar Vivadent) nas cores XL, A2, A3 e opaco foram misturados com a pasta catalisadora e inseridos dentro de um molde de teflon preto com (5 mm de diâmetro x 1 mm de espessura). A tira de poliéster transparente foi inserida sobre o molde e um disco da cerâmica (Duceram Plus, cor A3) foi posicionada sobre o cimento resinoso. A fotoativação foi realizada sobre o disco de cerâmica por 40 s usando a lâmpada de luz halógena (XL 2500, 3M ESPE) ou luz emitida por diodo (LED) com intensidade de luz de 615 e 610 mW/cm2. A dureza Knoop foi medida usando o microdurômetro HMV 2 (Shimadzu) com carga de 50 g por 15 s, após 15 min e 24 h. Quatro indentações foram feitas em cada amostra. Os dados foram submetidos à Análise de Variância e ao teste de Tukey (a=5 por cento). A fonte de luz halógena promoveu valores de dureza significantemente maiores (p<0,05) que o LED. Quando os tempos pós-polimerização foram comparados para a mesma cor, a luz halógena e o LED promoveram valores de dureza significantemente maiores (p<0,05) em 24 h do que aos 15 min. Pode-se concluir que, de maneira geral, a dureza Knoop foi dependente da fonte de luz e do tempo pós-polimerização. A cor opaca do cimento resinoso mostrou menores valores de dureza Knoop que as outras cores para ambas as fontes de luz e tempos pós-polimerização.


Subject(s)
Curing Lights, Dental , Dental Porcelain , Light-Curing of Dental Adhesives , Resin Cements , Analysis of Variance , Dental Stress Analysis , Hardness , Materials Testing , Resin Cements/chemistry , Resin Cements/radiation effects , Statistics, Nonparametric , Time Factors
9.
Rev. dental press estét ; 4(4): 32-38, out.-dez. 2007. ilus
Article in Portuguese | LILACS, BBO | ID: lil-529377

ABSTRACT

Durante a execução dos diversos tipos de tratamentos odontológicos, o cirurgião-dentista tem a necessidade e obrigação de registrar adequadamente, no prontuário odontológico, todos os procedimentos realizados na cavidade bucal, além das particularidades que o paciente já apresenta. A importância destes registros está relacionada a uma finalidade primordialmente clínica, visando propiciar o acompanhamento adequado dos tratamentos efetuados, a qualquer tempo. Entretanto, esta mesma documentação pode subsidiar relevantemente nos casos de identificação humana, principalmente nas situações em que os cadáveres encontram-se irreconhecíveis. Neste contexto, o presente trabalho tem como objetivo relatar um caso pericial em que um indivíduo encontrado carbonizado, em decorrência de acidente automobilístico seguido de incêndio, foi positivamente identificado com base nas anotações clínicas referentes à realização de um tratamento odontológico restaurador. A adequada qualidade dos registros odontológicos associada à resistência dos dentes remanescentes à ação do fogo permitiram que diversas particularidades odontológicas fossem identificadas, associando a pessoa desaparecida ao corpo carbonizado. Portanto, ressalta-se a importância dos registros odontológicos nos casos de identificação humana, evidenciando a necessidade do cirurgião-dentista atuar junto dos Institutos Médico-Legais, colaborando para esclarecimentos à justiça.


Subject(s)
Humans , Male , Adult , Dental Records , Forensic Anthropology , Forensic Dentistry/methods , Cadaver , Clinical Record , Medical History Taking
10.
JBC j. bras. clin. odontol. integr ; 10(55): 328-333, out.-dez. 2006. tab, graf, CD-ROM
Article in Portuguese | LILACS, BBO | ID: biblio-851593

ABSTRACT

A proposta deste estudo foi verificar a infiltração marginal de cavidades classe V utilizando resinas compostas posteriores. Foram preparados na face vestibular de 30 incisivos bovinos, preparos cavitários classe padronizada com término em esmalte. Em seguida, os dentes foram divididos em três grupos e restaurados utilizando os materiais de acordo com as instruções dos fabricantes, ou seja: Grupo I: Etch&Prime 3.0 (Degussa) + Definite (Degussa); Grupo II: Admira Bond (Voco) + Prodigy Condensable (Kerr) e Grupo III: Admira Bond (Voco) + Admira (Voco). Após restaurados, os dentes foram submetidos a 500 ciclos térmicos e isolados com esmalte para unha. Após, foram imersos em solução de azul de metileno a 2% tamponado, por 2 horas. Em seguida, foram seccionadas e analisadas em lupa estereoscópica para qualificar os níveis de infiltração. Os resultados foram analisados estatisticamente pelo teste Kruskal Wallis. Observou-se escore médio de 1,45 para o Grupo III, apresentando estatisticamente menor infiltração marginal, seguido do Grupo II (2,70) e posteriormente Grupo I (3,45), os quais diferiram entre si. O sistema restaurador Admira Bond + Admira apresentou menor infiltração diante dos demais sistemas restauradores


Subject(s)
Dental Marginal Adaptation , Composite Resins , Dental Leakage , Dental Cavity Preparation , Dentin-Bonding Agents , In Vitro Techniques , Data Interpretation, Statistical
11.
Arq. odontol ; 42(2): 140-146, 2006. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-457340

ABSTRACT

O propósito deste estudo foi avaliar o conteúdo de partícula inorgânica em massa e volume de resinas compostas de aplicação direta e indireta. Para a avaliação das partículas inorgânicas foram confeccionados cinco corpos-de-prova cilíndricos, com 5x2mm para cada material. Foram ativados por 40 segundos e pesados em balança analítica (Sartorius) à seco e imersos em água destilada. Após a eliminação da matriz orgânica realizada em forno elétrico a 700ºC por 3 horas, foram pesados à seco e armazenados em água destilada, por 7 dias para nova pesagem em imersão. O conteúdo por massa foi baseado na aplicação do Princípio de Arquimedes...


Subject(s)
Composite Resins/administration & dosage , Composite Resins/analysis , Compomers/administration & dosage , Compomers/analysis , Inorganic Particles/analysis
12.
Rev. ABO nac ; 11(4): 239-242, ago.-set. 2003. ilus
Article in Portuguese | LILACS, BBO | ID: lil-365730

ABSTRACT

Considerando importância da estética na odontologia, incluindo a ênfase que vem sendo apontada pelos fabricantes, pela mídia e pelos profissionais da área, este trabalho foi idealizado com intuito de colaborar, fornecendo informações com relação à proporcionalidade entre os dentes anteriores superiores no sentido mésio-distal. Foram selecionados estudantes de odontologia, com dentição natural para verificação clínica da presença da proporção áurea entre os dentes, pelo método proposto po Levin. A amostra era composta por 120 indivíduos, sendo 62 do sexo masculino e 58 do sexo feminino. Do total, 75,8 por cento tinham seus dentes anteriores superiores em proporção áurea, sendo observado ainda que 96,55 por cento das mulheres apresentam proporção áurea, conta somente 56,45 por cento do homens. Ao final, concluiu-se que, a aplicação da proporção áurea é uma ferramenta interessante para reconstrução de dentes anteriores superiores, particularmente para pacientes do sexo feminino.


Subject(s)
Humans , Male , Female , Adult , Dentition, Permanent , Esthetics, Dental
13.
RFO UPF ; 8(1): 46-49, jan.-jun. 2003. tab
Article in Portuguese | LILACS, BBO | ID: lil-391822

ABSTRACT

O próposito deste estudo foi avaliar a dureza Vickers e o conteúdo de partícula inorgânica de quatro compósitos de baixa viscosidade. Vinte corpos-de-prova cilindricos com 5 mm de diâmetro por 2 mm de profundidade foram confeccionados com as resinas compostas. Natural Flow (DFL), Flow it e Flow it LF (Jeneri/Pentron) e Revolution (kerr). A dureza Vickers foi mensurada no aparelho Wolpers com 50 gramas por 30 s, imediatamente e sete dias. Após a confecção dos corpos-de-prova. Doze penetrações foram feitas em cada amostra. Em seguida, foi feita a análise do conteúdo de partícula inôrganica, em massa e volume, numa balança analítica. Os resultados forma submetidos à análise de variância e ao teste de Fisher (p<0,05) e mostraram que a dureza Vickers imediata para a Flow It (44,52) e Flow It LF (40,64) foi estatisticamente superior à da Revolution (29,56) e da Natural Flow (27,89) (p<0,05). Após sete dias a dureza Vickers da Flow It (49,64) e Flow It (46,30) foi estatisticamente superior à Revolution (35,90) e da Natural Flow (28,61) (p<0,05). Para o conteúdo de partícula em massa, Natural Flow (51,60 por cento) e Revolution (53,80 por cento) apresentaram os menores valores percentuais, seguidas das resinas compostas Flow It(74,61 por cento) e Flow It LF (65,01 por cento). Em volume, Flow It (68,12 por cento) e Flow It LF (57,74 por cento) apresentaram valores percentuais superiores às resinas Natural Flow (40 por cento) e Revolution (46,80 po cento). Assim, as resinas Flow It e Flow It LF apresentaram maiores conteúdos de partícula inorgânica em massa e volume, além dos maiores valores de dureza imediata e sete dias após a fotoativação. Os valores de dureza obtidos aos sete dias foram maiores em relação aos valores iniciais, porém sem diferença estatística


Subject(s)
Composite Resins , Hardness , Inorganic Particles , Water Viscosity
14.
ROBRAC ; 8(26): 45-8, dez. 1999. graf
Article in Portuguese | LILACS, BBO | ID: lil-283605

ABSTRACT

Este trabalho verificou as relaçöes entre o tempo de profissäo dos cirurgiöes-dentistas, que trabalham sem auxiliar odontológico, com os possíveis problemas de coluna vertebral que venham a sofrer, afetando, consequentemente, o desmepenho clínico. Para tal, foram aplicados questionários em 105 CDs da cidade de Goiânia, Go, na faixa etària de 25 a 55 anos, divididos em três grupos: recém-formados há 5 anos; de 5 a 10 anos e, o último grupo, CD com mais de 10 anos de profissäo. Os resultados demonstraram que no decorrer dos anos da profissäo, houve um aumento significativo de dores nas regiöes de ombro e pescoço, associadas ao aumento de hábitos parafuncionais, diminuiçäo das atividades físicas e o estresse, como fator agravante na diminuiçäo do desempenho clínico


Subject(s)
Dentists , Habits , Spine , Stress, Physiological
SELECTION OF CITATIONS
SEARCH DETAIL